Corrosion Failure Analysis

As experienced, independent specialists, we provide rapid corrosion failure analysis services to help identify, investigate, and solve your corrosion-related issues – also on-site .

Corrosion can strike anywhere—whether at dizzying heights on a cooling tower or in narrow shafts of an industrial plant, from the North Sea to Brazil and Mexico…With extensive experience in the field of corrosion and corrosion protection, I look forward to tackling new challenges and providing expert solutions.
Steffen Six, CEO CorroConceptSteffen Six, Co-CEO, CorroConcept Korrosionsschutz Dresden GmbH

The Corrosion Failure Analysis Process

Step 1
Inquiry

Contact us by phone, email, or online meeting to discuss your corrosion problems. We will quickly send you a custom offer for your corrosion failure analysis. This includes possible on-site inspections and an estimate of the time needed.

Step 2
Investigation

After you approve the corrosion failure analysis and send us your samples, we begin a full investigation. Usually, we complete this in two to three weeks. We maintain communication should additional questions emerge during the analysis.

Step 3
Report

After concluding your corrosion failure analysis, you receive a detailed PDF report with clear explanations. Our team is ready to answer any questions you may have about your results.

Procedures and Methods of Corrosion Failure Analysis

On-Site Failure Analysis and Inspection Services

Our On-Site Corrosion Failure Analysis Services at a Glance

  • Mobile analysis of pH, electrical conductivity, and dissolved oxygen
  • Cross-cut testing (DIN EN ISO 2409, 16276-2)
  • Test of adhesion/cohesion (fracture strength) of a coating (DIN EN ISO 16276-1, 4624)
  • Film or coating thickness measurements (DIN EN ISO 2808, 2178)
  • Precise climate and dew point evaluation
  • Evaluation of degradation of coatings (DIN EN ISO 4628)
  • Surface salt and contaminant analysis (DIN/TR 55684)

Advanced Metallographic and Analytic Corrosion Failure Analysis

Our Lab and Metallography Services at a Glance

  • Scanning electron microscopy with EDX and XRF (through partner labs)
  • Eluate preparation for residue and deposit analysis
  • Measurement of pH, conductivity, dissolved oxygen, acid capacity (KS4.3), metal ions, and anions/cations